THE USE OF THE FOLLOWING NOTATION IN THIS EXHIBIT INDICATES THAT THE CONFIDENTIAL PORTION HAS BEEN OMITTED PURSUANT TO A REQUEST FORCONFIDENTIAL TREATMENT AND THE OMITTED MATERIAL HAS BEEN FILED SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION: [***] IntelsatOne Network Broadband Service Order No. 26622 Amendment 1
Exhibit 10.1.55
THE USE OF THE FOLLOWING NOTATION IN THIS EXHIBIT INDICATES THAT THE CONFIDENTIAL PORTION HAS BEEN OMITTED PURSUANT TO A REQUEST FOR CONFIDENTIAL TREATMENT AND THE OMITTED MATERIAL HAS BEEN FILED SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION: [***]
IntelsatOne Network Broadband Service Order No. 26622 Amendment 1
Intelsat Information: | Customer Information: | |||||
Name: | Intelsat Corporation (Intelsat) | Gogo LLC (Customer) | ||||
Place/Type of Organization: | A Delaware corporation | A Delaware corporation | ||||
Address: | 7900 Tysons One Place | 1250 N. Arlington Heights Road, Suite 500 | ||||
City/Country: | McLean, VA 22102 | Itasca, IL 60143 | ||||
Attention: | Suzette Schmidt | Bhavini Desai / Tim Joyce | ||||
Telephone: | +1 ###-###-#### | +1 ###-###-#### / +1 ###-###-#### | ||||
Facsimile: | +1 ###-###-#### | |||||
Email: | ***@*** | ***@*** / ***@*** | ||||
Type of Service Order | Amendment | |||||
Amendment Type | [***] | |||||
Master Service Agreement | Master Service Agreement No: 21078, dated 25-Aug-2008 Account No: 123639 | |||||
Service Start Date (SSD) of the Amended Service | [***] | |||||
Service End Date (SED) | 29-Feb-2016 or upon in-service of SatMex-7, whichever occurs earlier | |||||
Service Fee (Monthly Recurring Charge (MRC)) | See Service and Payment Schedule, below | |||||
Non-Recurring Charge (NRC) | ||||||
Deposit/Collateral | Not Required | |||||
Billing Method | Monthly in Advance | |||||
Appendices | Appendix 1: Appendix 2: Appendix 3: Appendix 4: | Service Details Napa Teleport Operational Contact Details Collocation Service Details Roles and Responsibilities of Intelsat and Gogo for VNO and Hub Lease Service Options | ||||
Appendix 5: Appendix 6: | Additional Terms and Conditions Forward and Return Link Budgets |
Service and Payment Schedule | ||||||||||||||
Service Start Date | Service End Date | Destination | Type of Service | Service ID Nos. | NRC | MRC | ||||||||
1-Mar-2014 | 14-Jun-2015 | Napa | Uplink Ku-1 beam [***] | [***] | ||||||||||
15-Jun-2015 | 29-Feb-2016 /* | Napa | Uplink Ku-1 beam [***] | |||||||||||
Uplink Ku-2 beam
Collocation in Napa (SatMex-5 Uplink) | ||||||||||||||
15-Jun-2015 | 29-Feb-2016 /* | Napa | Napa [***] | |||||||||||
Napa Internet Access [***] | ||||||||||||||
1-Mar-2014 through 14-Jun-2015 | Previous Totals | [***] | [***] | |||||||||||
15-Jun-2015 through 29-Feb-2016 /* | New TOTALS | [***] | [***] |
*/ | 29-Feb-2016 or upon in-service of SatMex-7, whichever occurs earlier |
** | [***] |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 1 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
By signing and returning this Service Order No. 26622 Amendment No. 1 (Service Order) to Intelsat, Customer is making an offer to purchase the service described in this Service Order (Service) from Intelsat. When executed by Intelsat, this Service Order shall become binding. Provision of the Service is subject to Intelsat receiving from Customer any required Deposit/Collateral specified in a form acceptable to Intelsat at least fifteen (15) calendar days prior to the Service Start Date. Intelsat may apply the Deposit/Collateral paid hereunder to cover any outstanding payments due by Customer to Intelsat under this Service Order or any other Service Order subject to the terms and conditions of the MSA set forth above. Intelsat shall return any remaining Deposit/Collateral or security to Customer once all Services under the MSA have been terminated and liabilities have been settled. This Service Order incorporates the Appendices listed above, and the applicable Service Descriptions for the Service which are available at https://my.Intelsat.com and which may be revised from time to time by Intelsat. The terms and conditions of the Master Service Agreement (MSA) referenced above shall apply to this Service Order and are incorporated by reference. Parties hereby agree that as of the Service Start Date set forth herein, Service Order No. 26622 is immediately terminated and replaced by this Service Order No. 26622 Amendment No. 1, which shall be effective as of the same date.
INTELSAT CORPORATION | GOGO LLC | |||||||
By: | /s/ Stephen Chernow | By: | /s/ Tim Joyce | |||||
Name: | Stephen Chernow | Name: | Tim Joyce | |||||
Title: | Vice President & Deputy General Counsel | Title: | VP RF Engineer | |||||
Date: | August 11, 2015 | Date: | August 10, 2015 |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 2 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
Appendix 1 Service Details Napa Teleport
Napa Teleport Master
Service Type | VNO (as a Hub Lease) | |
Service Mode (Choose One) | Evolution DVB-S2 with ACM (iDX 2.0.1 or higher) | |
Operating Software Version | iDX 3.1.0.3 (DVB-S2) - Customer agrees and acknowledges that they will use iDX 3.1.0.3 software at installation and thereafter the Customer will be free to utilize any software they require. | |
Group QoS (Choose One) | Hub Lease (see appendix for details) |
SVO-515033-100 Uplink/Downlink and Hub (NBB-T)
Satellite and Orbital Location | Satellite: Satmex-5 Location: 245.1°E | |
Transponder No. | Intelsat to Customer site: [***] Kbps Customer site to Intelsat: [***] Kbps (Forward) (Return) | |
Beam | Ku-1 | |
Service Info Rate (Kbps) Data Rate + Overhead | Previous configuration: Network #1: Forward Info rate: [***] Return Info rate: [***] Aggregate Info Rate: [***]
New Configuration: Network #1: Forward Info rate: [***] Return Info rate: [***] Aggregate Info Rate: [***] | |
Total Bandwidth Required (MHz) | [***] MHz Refer to Service Order/OSC No. 26546, Amendment 1 SVO No. 515035 | |
CPT Details | Modem type and model No: iDirect 8350 Antenna Size: [***] BUC/HPA size: [***] G/T (mid-band) [***] Tx gain (mid-band) [***] | |
Service Coverage Area | US/Canada | |
Hub Equipment | Number of Protocol Processor: 2 Number of NMS: 0 Number of Line Card: 2 XLC-11 | |
Service Demarcation Points | Point A: One cm in front of the customer antenna feed Point B: IFL connection to chassis Point C: Ethernet connection of chassis Point Z: Intelsat Internet access router port |
SVO-515033-101 Uplink/Downlink and Hub (NBB-T) no change
Satellite and Orbital Location | Satellite: Satmex-5 Location: 245.1°E | |
Transponder No. | Intelsat to Customer site: [***] Kbps Customer site to Intelsat: [***] Kbps (Forward) (Return) | |
Beam | Ku-2 | |
Service IP Data Rate (Kbps) | Initial configuration: Network #1: Forward Info rate: [***] Return Info rate: [***] Aggregate Info Rate: [***] | |
Total Bandwidth Required (Mhz) | Reference [***] MHz - Refer to Service Order/OSC No. 26546 SVO No. 515082 | |
CPT Details | Modem type and model No: iDirect e8350 Antenna Size: [***] BUC/HPA size: [***] G/T (mid-band) [***] Tx gain (mid-band) [***] | |
Service Coverage Area | US, Central, and South America | |
Hub Equipment | Number of Protocol Processor: 0 Number of NMS: 0 Number of Line Card: 2 XLC-11 | |
Service Demarcation Points | Point A: One cm in front of the customer antenna feed Point B: IFL connection to chassis Point C: Ethernet connection of chassis Point Z: Intelsat Internet access router port |
SVO-515033-102 Collocation no change
Collocation | Yes (see Collocation Service details) |
SVO-515033-103 Ethernet Private Line Connectivity no change
Fiber Extension Between Pops Or Teleports | Yes [***] via IntelsatOne (see Additional Terms and Conditions) | |
Local Loop | Terminating Location (Interconnection point with Intelsat): (addresses are provided in Section VII) Patch panel at Intelsat Teleport: Napa Patch panel at Intelsat POP: [***] Circuit Type: Ethernet Private Line |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 3 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
SVO-515033-104 no change
Internet Access | Yes Data Rate = [***] |
When Adaptive Code and Modulation (ACM) is not employed, the Maximum IP Data Rate will be equal to the Minimum IP Data Rate. When ACM is employed, this Service Order guarantees the Forward Minimum IP Data Rate at the minimum modulation scheme (see Forward Carrier Parameters) and the Return IP Data Rate (s).
Additional forward IP data rate, achieved through the use of ACM up to the Forward Maximum IP Data Rate is provided on a best effort basis.
The Minimum IP Data Rate must result in a symbol rate of no less than 1MSps
Notes:
| Global code: The DVB-S2 specification defines a concatenation of Low Density Parity Check (LDPC) code and Bose-Chaudhuri- Hocquenghem (BCH) codes. This results in a higher FEC overhead reflected in link budgets by the global code rate. |
| Intelsat Network Broadband Service supports VoIP and VPN by enabling clear dedicated access channel between the network hub and remote site modem. VoIP/VPN support over Intelsat Network Broadband Service is limited to transport of VoIP packets from the remote VSAT Units Ethernet port to Intelsats multi-homed internet backbone. Selection of a VoIP service provider and termination with them is expected to be arranged by the Customer. Similarly, provision of any VPN hardware and software for end-users end-to-end secure application is expected to be arranged by the Customer. The Customer is also responsible for setting up VoIP/VPN functionalities, such as routing, gateway configuration, call setup, control, billing, etc. |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 4 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
Appendix 2 - Operational Contact Details
Customer Technical Contact
Name | Bryan Lauer, VP Systems Engineering | |
Phone | +1 ###-###-#### | |
Mobile | +1 ###-###-#### | |
E-mail address | ***@*** |
Customer Earth Station Contact
Earth Station Name | Gogo LLC, Network Operations Center | |
Earth Station Manager | NOC Engineer on Duty | |
Street address | 1250 North Arlington Heights Rd | |
City, State | Itasca, IL 60134 | |
Country | USA | |
Phone | +1 ###-###-#### | |
Mobile | ||
E-mail address | ***@*** |
Intelsat Contact Details
Intelsat Teleport address | Napa Teleport 961 Anselmo Court, Napa, CA 94558, USA | |||
Intelsat POP | New York POP, Level 3, 111 8th Avenue, Suite 304, New York, NY 10011, USA Various - For network diversity | |||
Sales Director | Name: Tel: Email: | Fernando Freitas +1 ###-###-#### ***@*** | ||
Solutions Engineer | Name: Tel: Email: | Christopher Kinard +1 ###-###-#### ***@*** | ||
Provisioning Team | ***@*** (pre-sales and provisioning M-F 8 am 5 pm Eastern US Time) ***@*** (off hours support 24 x 7 x 365) |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 5 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
Appendix 3 Service Collocation Service Details
Intelsat Collocation services are provided subject to the terms and conditions of Intelsats Customer Collocation
Services Handbook which can be located at https://my.intelsat.com/_files/resources/IntelsatOne_Customer_Collocation_Services_Handbook.pdf
Intelsat shall provide one (1) Transmit and one (1) Receive cable to the Customer Collocation rack of equipment for each transponder listed in Appendix 1 of this Service Order. Intelsat will provide a Receive, Single-Carrier Level of -40dBm +/- 5dB. If Customer requires greater Receive Power level, upon request Intelsat can provide increased amplified signal for an additional charge.
Collocation site name | Name: [***] | |
List of equipment
Note 1: Intelsat requires an exhaustive inventory of the equipment to be installed at Intelsat Teleport.
Note 2: All co-located equipment must be 19 inches rack mountable
Note 3: Intelsat does not bear any import VAT, duties or shipment costs applicable to the equipment not owned by Intelsat and delivered to any Intelsat facility. | [***] |
Item | Service Details | Notes / Service terms | ||
No. of rack units (RU)/rack | 11 RU(s) 1 Rack(s) Racks to be provided by Intelsat | All racks are standard 19 inch racks. Rack height varies by teleport. Please see Intelsats Customer Collocation Handbook for rack height for the selected teleport. | ||
No. of power outlets | Customer supplied PDU | The number of allowable power outlets without extra charge is limited to 1 per RU, 4 per half rack and 8 per full rack on the same power source. Additional power outlets are available in increments of 8 and are subject to an additional NRC of [***] for each set of 8 power outlets under the same power source. If a different power source is required, item #5 will apply. (*) | ||
No. of power sources | 2 power sources | The number of allowable power sources without extra charge is limited to 1 per rack. Additional power sources are available and are subject to an additional NRC of [***] for each additional source and an additional MRC of [***] per RU, [***] per half rack and [***] per full rack. The number of outlets provided per additional power source is as per item #4. (*) | ||
Total power consumption | 2x20 Amps power sources each (total 40Amps) | The allowable power without extra charge is limited to 20 Amps per rack. Additional power requirements are subject to an additional NRC of [***] per 20 amps increment and an additional MRC of [***] per RU, [***] per half rack and [***] per full rack. (*) | ||
Remote access | Internet access Data rate 2 Mbit/s | Remote Internet access is available to allow customers to control and monitor equipment. Please indicate the data rate required for remote monitoring access (e.g. do not put the data rate here for your satellite carriers, but instead the rate for remote Internet access for equipment monitoring).
Outgoing phone lines are not available at the Teleport. Incoming dial-up access lines are subject to a location fee and a line rate dependent upon the amount charged by the local telecom providers. If Internet access is required, the co-located equipment must have an Ethernet port. (*) | ||
Cross-connect required to other customer | Yes - Customer agrees to be responsible for the interconnection to CenturyLink located at 111 8th Ave., NYC | The other customer authorization must be provided to Intelsat to establish the cross-connect. | ||
No. of Teleport access cards | 0 | Intelsat shall provide the Customer access to its Teleport for installation of Customer-provided equipment, for emergency operation and maintenance and for any required Intelsat SSOG test and network activation tests. Any visit to Intelsat facilities, such as Teleport, should be coordinated with Intelsat in advance. The Customer will normally be allowed to have a maximum of two persons on site to support the service detailed in this Service Order. | ||
Assistance required for equipment installation | No | Intelsats Collocation MRC and NRC do not includes the provision of any labor to assemble and rack mount Customers co-located equipment. Any such assistance must be requested separately and is charged as per level 1 support charges presented in row 11 below. |
(*) | 1. | Please contact our Provisioning team at ***@*** for your additional power, power outlets and remote access requirements, if any. | ||
2. | A separate invoice will be issued for these above additional requirements. |
Item | Level 1 support charges per hour | Level 1 support details | ||
Level 1 support | 7 days a week 0800-1700: [***] (local time)
Note: Level 1 support labor is not included in the Collocation rack space charges. Labor will be invoiced for a minimum of one hour and then per additional half hour increment. Any additional special labor or material expenses will be charged at cost [***]. | Intelsat will provide the following services as part of Level 1 support when requested by the Customer to the NOC:
Re-booting of Customer equipment.
Changing cards as guided by Customer.
Customer must provide spare cards.
Swapping cards as advised by Customer.
Checking LED status, as requested and guided by the Customer. | ||
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 6 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
Appendix 4 - Roles and Responsibilities of
Intelsat and Gogo for VNO and Hub Lease Service Options
Hardware | Hub Lease | |
iDirect hub hardware investment (Hub chassis, line cards, back-up line cards and protocol processors) | Intelsat | |
IP hardware infrastructure at teleports (switches, routers etc.) | Gogo | |
Investment in GNMS | Gogo | |
NMS client software investment | Gogo | |
Procurement of equipment co-located at Intelsat Teleport | Gogo | |
Procurement of aircraft terminals | Gogo | |
Services | Hub Lease | |
Space segment sizing and hub commissioning | Intelsat | |
Commissioning of routers, switches etc | Gogo | |
Teleport services (RF uplink and downlink) | Intelsat | |
Intelsat Internet backbone connectivity | Intelsat | |
Intelsat MPLS, Metro Ethernet, VPN commissioning | Intelsat | |
Set up and modification of carriers in NMS with iBuilder | Gogo | |
Set up and modification of traffic profiles in NMS with iBuilder | Gogo | |
Network management and monitoring with iMonitor | Gogo | |
Software upgrades | Gogo | |
Repair and replacement of failed iDirect hub hardware | Intelsat after notification by Gogo | |
Repair and replacement of failed teleport hardware (excluding iDirect hub hardware see above) | Intelsat | |
Remote site configuration in NMS with iBuilder: Set up / modification of assignment of remotes to carriers Set up / modification of QOS profiles | Gogo | |
Remote equipment installation | Gogo | |
Cross-polarization isolation and 1 dB compression tests (or comparable tests if unavailable due to antenna limitations) | Gogo with support of Intelsat CMC | |
Hardware | Hub Lease | |
Generation of the option files required for the iDirect modem configuration through iBuilder | Gogo. Intelsat support where necessary | |
Loading of the option file on the remote iDirect modem and upgrade of this option file if required | Gogo | |
Remote software compatibility | Gogo | |
Remote equipment maintenance | Gogo | |
Remote software version | Gogo | |
Remote software upgrade | Over the air by Gogo. Remote support by Gogo | |
Installation, Collocation, management and maintenance of co-located equipment at Intelsat Teleport | Gogo | |
Integration of traffic via non-Intelsat teleports and non-Intelsat satellite capacity with this proposed network | Gogo | |
Integration of traffic via Intelsat teleports and non-Intelsat satellite capacity with this proposed network | Intelsat | |
Creation of beam map files in support of automatic beam switching | Intelsat (for Intelsat satellites only) | |
Setting up of helpdesk and Level 1 support to end users* | Gogo | |
Training of end users | Gogo | |
Local and national licensing | Gogo | |
Level 1 support to end users* | Gogo | |
24 x 7 Level 2 support* | Gogo | |
24 x 7 Level 3 support* | Intelsat | |
Application support | Gogo |
Support Levels for Network Broadband Service
Support Level | Description of Support | |
Level 1 | All end-user support including initial site configuration, subsequent equipment trouble shooting and site-specific technical & QOS issues | |
Level 2 | Support related to remote configuration issues in the NMS such as assignment or modification of a carrier or a QoS profile to a remote in the NMS. | |
Level 3 | Customer support related to network wide issues as carrier configuration issues, QoS profile configuration issues, space segment, or hub equipment and hub IP configuration issues. | |
Level 4 | Vendor support related to network wide issues which require software, firmware, or hardware modification/upgrade |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 7 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
Appendix 5 - Additional Terms and Conditions
1. | [***] |
2. | [***] |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 8 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
Appendix 6 Forward and Return Link Budgets
(KU-1 and KU-2 Beams, SATMEX 5 @ 114.9 W)
Rev 3
[***]
July 3, 2013
Beam/Pointing | From | To | EIRP | Skew | LB Name | Type | Data | Mod/Spread | FEC | PFD dBW/4kHz | Margin | BWM | % BW | Power | % | |||||||||||||||
Ku-1 | Napa | NE. Canada | [***] | |||||||||||||||||||||||||||
Ku-2 | Napa | Guadelupe | ||||||||||||||||||||||||||||
Ku-1 | NE. Canada | Napa | ||||||||||||||||||||||||||||
Ku-2 | Guadalupe | Napa |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 9 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
GOGO FORWARD IDIRECT AEROSAT
7/ 2/2013 SMSKJEI | ||||
FROM: NAPA | TO: NE CANADA |
REQUIREMENTS | SATELLITE | |||
Availability (%): [***] | *Satellite SATMEX [***] | |||
*Required Eb/No (dB): [***] | Satellite West Long : [***] | |||
*Bit Error Rate : QEF | *Transponder [***] | |||
*Modulation Type : QPSK | !Usable Trnspndr BW (MHz): [***] | |||
*Info. Rate (Kbps): [***] | !SFD @ 0 dB/K (dBW/M^2): [***] | |||
*FEC Rate : [***] | *Transponder Atten (dB): [***] | |||
*Spread Spectrum Factor : [***] | ||||
*Modem Step Size (kHz): [***] |
TRANSMIT E/S | RECEIVE E/S | |||
North Lat: [***] West Long: [***] | North Lat: [***] West Long: [***] | |||
!Frequency (GHz): [***] | !Frequency (GHz): [***] | |||
*Satellite G/T (dB/K): [***] | *Satellite EIRP (dBW): [***] | |||
*Antenna Diameter (m): [***] | *Antenna Diameter (m): [***] | |||
*Antenna Gain (dBi): [***] | *Antenna Gain (dBi): [***] | |||
Antenna Elevation (Deg): [***] | Antenna Elevation (Deg): [***] | |||
Carrier EIRP (dBW): [***] | LNA Noise Temp (K): [***] | |||
*Power Control (dB): [***] | *Loss betw.LNA & Ant.(dB): [***] | |||
*Output Circuit Loss (dB): [***] | System Noise Temp. (K): [***] | |||
Path Loss (dB): [***] | *Station G/T (dB/K): [***] | |||
*Other Losses (dB): [***] | Path Loss (dB): [***] | |||
(other loss = atm,pol,ant point) | *Other Losses (dB): [***] |
INTERFERENCE | ||||
C/Io Adj Sat U (dB-Hz): [***] | #C/Io Intermod (dB-Hz): [***] | |||
#C/Io Adj Sat D (dB-Hz): [***] | C/No Thermal Up (dB-Hz): [***] | |||
#C/Io Crosspol (dB-Hz): [***] | C/No Thermal Dn (dB-Hz): [***] | |||
C/Io Adj Channel (dB-Hz): [***] | C/Io Total (dB-Hz): [***] | |||
C/Io Adj Trans (dB-Hz): [***] | C/No Therm Total (dB-Hz): [***] | |||
C/Io Microwave (dB-Hz): [***] | C/No Total (dB-Hz): [***] |
RAIN ATTENUATION | ||||
Overall Link Margin (dB): [***] | *Rain Model : CRANE | |||
Uplink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Uplink Rain Zone : C | |||
Dnlink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Dnlink Rain Zone : A | |||
G/T Degradation (dB): [***] |
TRANSPONDER | H.P.A | |||
*Number of Carriers : MULTIPLE | *Number of Carriers : [***] | |||
*Total OPBO (dB): [***] | *Total HPA OPBO : [***] | |||
Total IPBO (dB): [***] | HPA Power/Carrier (dBm): [***] | |||
*Carrier OPBO (dB): [***] | Required HPA Size (dBW): [***] | |||
Carrier IPBO (dB): [***] | Required HPA Size (W): [***] | |||
FCC Req: 1) Uplink Flange Density (dBW/[***]kHz): [***] File: SMX5GF08 | ||||
(@[***]) 2) Downlink EIRP Density (dBW/[***]kHz): [***] | ||||
Transponder BW Used Per Carrier (x[***]) (%): [***] # = deltas used | ||||
Transponder Power Used Per Carrier (%): [***] ! = modif. default | ||||
Transponder Bandwidth Allocation (MHz): [***] * = users input |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 10 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
GOGO FORWARD IDIRECT AEROSAT | ||||
7/ 2/2013 SMSKJEI | ||||
FROM: NAPA | TO: BASSE TERRE GUADELUP |
REQUIREMENTS | SATELLITE | |||
Availability (%): [***] | *Satellite SATMEX [***] | |||
*Required Eb/No (dB): [***] | Satellite West Long : [***] | |||
*Bit Error Rate : QEF | *Transponder [***] | |||
*Modulation Type : QPSK | !Usable Trnspndr BW (MHz): [***] | |||
*Info. Rate (Kbps): [***] | !SFD @ 0 dB/K (dBW/M^2): [***] | |||
*FEC Rate : [***] | *Transponder Atten (dB): [***] | |||
*Spread Spectrum Factor : [***] | ||||
*Modem Step Size (kHz): [***] |
TRANSMIT E/S | RECEIVE E/S | |||
North Lat: [***] West Long: [***] | North Lat: [***] West Long: [***] | |||
!Frequency (GHz): [***] | !Frequency (GHz): [***] | |||
*Satellite G/T (dB/K): [***] | *Satellite EIRP (dBW): [***] | |||
*Antenna Diameter (m): [***] | *Antenna Diameter (m): [***] | |||
*Antenna Gain (dBi): [***] | *Antenna Gain (dBi): [***] | |||
Antenna Elevation (Deg): [***] | Antenna Elevation (Deg): [***] | |||
Carrier EIRP (dBW): [***] | LNA Noise Temp (K): [***] | |||
*Power Control (dB): [***] | *Loss betw.LNA & Ant.(dB): [***] | |||
*Output Circuit Loss (dB): [***] | System Noise Temp. (K): [***] | |||
Path Loss (dB): [***] | *Station G/T (dB/K): [***] | |||
*Other Losses (dB): [***] | Path Loss (dB): [***] | |||
(other loss = atm,pol,ant point) | *Other Losses (dB): [***] |
INTERFERENCE | ||||
C/Io Adj Sat U (dB-Hz): [***] | #C/Io Intermod (dB-Hz): [***] | |||
#C/Io Adj Sat D (dB-Hz): [***] | C/No Thermal Up (dB-Hz): [***] | |||
#C/Io Crosspol (dB-Hz): [***] | C/No Thermal Dn (dB-Hz): [***] | |||
C/Io Adj Channel (dB-Hz): [***] | C/Io Total (dB-Hz): [***] | |||
C/Io Adj Trans (dB-Hz): [***] | C/No Therm Total (dB-Hz): [***] | |||
C/Io Microwave (dB-Hz): [***] | C/No Total (dB-Hz): [***] |
RAIN ATTENUATION | ||||
Overall Link Margin (dB): [***] | *Rain Model : CRANE | |||
Uplink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Uplink Rain Zone : C | |||
Dnlink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Dnlink Rain Zone : A | |||
G/T Degradation (dB): [***] |
TRANSPONDER | H.P.A | |||
*Number of Carriers : MULTIPLE | *Number of Carriers : [***] | |||
*Total OPBO (dB): [***] | *Total HPA OPBO : [***] | |||
Total IPBO (dB): [***] | HPA Power/Carrier (dBm): [***] | |||
*Carrier OPBO (dB): [***] | Required HPA Size (dBW): [***] | |||
Carrier IPBO (dB): [***] | Required HPA Size (W): [***] | |||
FCC Req: 1) Uplink Flange Density (dBW/[***]kHz): [***] File: SMX5GF08 | ||||
(@[***]) 2) Downlink EIRP Density (dBW/[***]kHz): [***] | ||||
Transponder BW Used Per Carrier (x[***]) (%): [***] # = deltas used | ||||
Transponder Power Used Per Carrier (%): [***] ! = modif. default | ||||
Transponder Bandwidth Allocation (MHz): [***] * = users input |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 11 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
GOGO RETURN IDIRECT AEROSAT | ||||
7/ 3/2013 SMSKJEI | ||||
FROM: NE CANADA | TO: NAPA | |||
REQUIREMENTS | SATELLITE | |||
Availability (%): [***] | *Satellite SATMEX [***] | |||
*Required Eb/No (dB): [***] | Satellite West Long : [***] | |||
*Bit Error Rate : QEF | *Transponder [***] | |||
*Modulation Type : QPSK | !Usable Trnspndr BW (MHz): [***] | |||
*Info. Rate (Kbps): [***] | !SFD @ 0 dB/K (dBW/M^2): [***] | |||
*FEC Rate : [***] | *Transponder Atten (dB): [***] | |||
*Spread Spectrum Factor : [***] | ||||
*Modem Step Size (kHz): [***] | ||||
TRANSMIT E/S | RECEIVE E/S | |||
North Lat: [***] West Long: [***] | North Lat: [***] West Long: [***] | |||
!Frequency (GHz): [***] | !Frequency (GHz): [***] | |||
*Satellite G/T (dB/K): [***] | *Satellite EIRP (dBW): [***] | |||
*Antenna Diameter (m): [***] | *Antenna Diameter (m): [***] | |||
*Antenna Gain (dBi): [***] | *Antenna Gain (dBi): [***] | |||
Antenna Elevation (Deg): [***] | Antenna Elevation (Deg): [***] | |||
Carrier EIRP (dBW): [***] | LNA Noise Temp (K): [***] | |||
*Power Control (dB): [***] | *Loss betw.LNA & Ant.(dB): [***] | |||
*Output Circuit Loss (dB): [***] | System Noise Temp. (K): [***] | |||
Path Loss (dB): [***] | *Station G/T (dB/K): [***] | |||
*Other Losses (dB): [***] | Path Loss (dB): [***] | |||
(other loss = atm,pol,ant point) | *Other Losses (dB): [***] | |||
INTERFERENCE | ||||
C/Io Adj Sat U (dB-Hz): [***] | #C/Io Intermod (dB-Hz): [***] | |||
#C/Io Adj Sat D (dB-Hz): [***] | C/No Thermal Up (dB-Hz): [***] | |||
#C/Io Crosspol (dB-Hz): [***] | C/No Thermal Dn (dB-Hz): [***] | |||
C/Io Adj Channel (dB-Hz): [***] | C/Io Total (dB-Hz): [***] | |||
C/Io Adj Trans (dB-Hz): [***] | C/No Therm Total (dB-Hz): [***] | |||
C/Io Microwave (dB-Hz): [***] | C/No Total (dB-Hz): [***] | |||
RAIN ATTENUATION | ||||
Overall Link Margin (dB): [***] | *Rain Model : CRANE | |||
Uplink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Uplink Rain Zone : A | |||
Dnlink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Dnlink Rain Zone : F | |||
G/T Degradation (dB): [***] |
TRANSPONDER | H.P.A | |||
*Number of Carriers : MULTIPLE | *Number of Carriers : [***] | |||
*Total OPBO (dB): [***] | *Total HPA OPBO : [***] | |||
Total IPBO (dB): [***] | HPA Power/Carrier (dBm): [***] | |||
*Carrier OPBO (dB): [***] | Required HPA Size (dBW): [***] | |||
Carrier IPBO (dB): [***] | Required HPA Size (W): [***] | |||
FCC Req: 1) Uplink Flange Density (dBW/[***]kHz): [***] File: SMX5GF08 | ||||
(@[***]) 2) Downlink EIRP Density (dBW/[***]kHz): [***] | ||||
Transponder BW Used Per Carrier (x[***]) (%): [***] # = deltas used | ||||
Transponder Power Used Per Carrier (%): [***] ! = modif. default | ||||
Transponder Bandwidth Allocation (MHz): [***] * = users input |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 12 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
GOGO FORWARD IDIRECT AEROSAT | ||||
7/ 2/2013 SMSKJEI | ||||
FROM: NAPA | TO: BASSE TERRE GUADELUP | |||
REQUIREMENTS | SATELLITE | |||
Availability (%): [***] | *Satellite SATMEX [***] | |||
*Required Eb/No (dB): [***] | Satellite West Long : [***] | |||
*Bit Error Rate : QEF | *Transponder [***] | |||
*Modulation Type : QPSK | !Usable Trnspndr BW (MHz): [***] | |||
*Info. Rate (Kbps): [***] | !SFD @ 0 dB/K (dBW/M^2): [***] | |||
*FEC Rate : [***] | *Transponder Atten (dB): [***] | |||
*Spread Spectrum Factor : [***] | ||||
*Modem Step Size (kHz): [***] | ||||
TRANSMIT E/S | RECEIVE E/S | |||
North Lat: [***] West Long: [***] | North Lat: [***] West Long: [***] | |||
!Frequency (GHz): [***] | !Frequency (GHz): [***] | |||
*Satellite G/T (dB/K): [***] | *Satellite EIRP (dBW): [***] | |||
*Antenna Diameter (m): [***] | *Antenna Diameter (m): [***] | |||
*Antenna Gain (dBi): [***] | *Antenna Gain (dBi): [***] | |||
Antenna Elevation (Deg): [***] | Antenna Elevation (Deg): [***] | |||
Carrier EIRP (dBW): [***] | LNA Noise Temp (K): [***] | |||
*Power Control (dB): [***] | *Loss betw.LNA & Ant.(dB): [***] | |||
*Output Circuit Loss (dB): [***] | System Noise Temp. (K): [***] | |||
Path Loss (dB): [***] | *Station G/T (dB/K): [***] | |||
*Other Losses (dB): [***] | Path Loss (dB): [***] | |||
(other loss = atm,pol,ant point) | *Other Losses (dB): [***] | |||
INTERFERENCE | ||||
C/Io Adj Sat U (dB-Hz): [***] | #C/Io Intermod (dB-Hz): [***] | |||
#C/Io Adj Sat D (dB-Hz): [***] | C/No Thermal Up (dB-Hz): [***] | |||
#C/Io Crosspol (dB-Hz): [***] | C/No Thermal Dn (dB-Hz): [***] | |||
C/Io Adj Channel (dB-Hz): [***] | C/Io Total (dB-Hz): [***] | |||
C/Io Adj Trans (dB-Hz): [***] | C/No Therm Total (dB-Hz): [***] | |||
C/Io Microwave (dB-Hz): [***] | C/No Total (dB-Hz): [***] | |||
RAIN ATTENUATION | ||||
Overall Link Margin (dB): [***] | *Rain Model : CRANE | |||
Uplink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Uplink Rain Zone : C | |||
Dnlink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Dnlink Rain Zone : A | |||
G/T Degradation (dB): [***] |
TRANSPONDER | H.P.A | |||
*Number of Carriers : MULTIPLE | *Number of Carriers : [***] | |||
*Total OPBO (dB): [***] | *Total HPA OPBO : [***] | |||
Total IPBO (dB): [***] | HPA Power/Carrier (dBm): [***] | |||
*Carrier OPBO (dB): [***] | Required HPA Size (dBW): [***] | |||
Carrier IPBO (dB): [***] | Required HPA Size (W): [***] | |||
FCC Req: 1) Uplink Flange Density (dBW/[***]kHz): [***] File: SMX5GF08 | ||||
(@[***]) 2) Downlink EIRP Density (dBW/[***]kHz): [***] | ||||
Transponder BW Used Per Carrier (x[***]) (%): [***] # = deltas used | ||||
Transponder Power Used Per Carrier (%): [***] ! = modif. default | ||||
Transponder Bandwidth Allocation (MHz): [***] * = users input |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 13 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |
KU-2 BEAM ORIGINAL POINTING GOGO RETU | ||||
7/ 3/2013 SMSKJEI | ||||
FROM: BASSE TERRE | TO: NAPA | |||
REQUIREMENTS | SATELLITE | |||
Availability (%): [***] | *Satellite SATMEX [***] | |||
*Required Eb/No (dB): [***] | Satellite West Long : [***] | |||
*Bit Error Rate : QEF | *Transponder [***] | |||
*Modulation Type : QPSK | !Usable Trnspndr BW (MHz): [***] | |||
*Info. Rate (Kbps): [***] | !SFD @ 0 dB/K (dBW/M^2): [***] | |||
*FEC Rate : [***] | *Transponder Atten (dB): [***] | |||
*Spread Spectrum Factor : [***] | ||||
*Modem Step Size (kHz): [***] | ||||
TRANSMIT E/S | RECEIVE E/S | |||
North Lat: [***] West Long: [***] | North Lat: [***] West Long: [***] | |||
!Frequency (GHz): [***] | !Frequency (GHz): [***] | |||
*Satellite G/T (dB/K): [***] | *Satellite EIRP (dBW): [***] | |||
*Antenna Diameter (m): [***] | *Antenna Diameter (m): [***] | |||
*Antenna Gain (dBi): [***] | *Antenna Gain (dBi): [***] | |||
Antenna Elevation (Deg): [***] | Antenna Elevation (Deg): [***] | |||
Carrier EIRP (dBW): [***] | LNA Noise Temp (K): [***] | |||
*Power Control (dB): [***] | *Loss betw.LNA & Ant.(dB): [***] | |||
*Output Circuit Loss (dB): [***] | System Noise Temp. (K): [***] | |||
Path Loss (dB): [***] | *Station G/T (dB/K): [***] | |||
*Other Losses (dB): [***] | Path Loss (dB): [***] | |||
(other loss = atm,pol,ant point) | *Other Losses (dB): [***] | |||
INTERFERENCE | ||||
C/Io Adj Sat U (dB-Hz): [***] | #C/Io Intermod (dB-Hz): [***] | |||
#C/Io Adj Sat D (dB-Hz): [***] | C/No Thermal Up (dB-Hz): [***] | |||
#C/Io Crosspol (dB-Hz): [***] | C/No Thermal Dn (dB-Hz): [***] | |||
C/Io Adj Channel (dB-Hz): [***] | C/Io Total (dB-Hz): [***] | |||
C/Io Adj Trans (dB-Hz): [***] | C/No Therm Total (dB-Hz): [***] | |||
C/Io Microwave (dB-Hz): [***] | C/No Total (dB-Hz): [***] | |||
RAIN ATTENUATION | ||||
Overall Link Margin (dB): [***] | *Rain Model : CRANE | |||
Uplink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Uplink Rain Zone : A | |||
Dnlink Availability (%): [***] | ||||
Rain Margin (dB): [***] | *Dnlink Rain Zone : C | |||
G/T Degradation (dB): [***] |
TRANSPONDER | H.P.A | |||
*Number of Carriers : MULTIPLE | *Number of Carriers : [***] | |||
*Total OPBO (dB): [***] | *Total HPA OPBO : [***] | |||
Total IPBO (dB): [***] | HPA Power/Carrier (dBm): [***] | |||
*Carrier OPBO (dB): [***] | Required HPA Size (dBW): [***] | |||
Carrier IPBO (dB): [***] | Required HPA Size (W): [***] | |||
FCC Req: 1) Uplink Flange Density (dBW/[***]kHz): [***] File: SMX5GF08 | ||||
(@[***]) 2) Downlink EIRP Density (dBW/[***]kHz): [***] | ||||
Transponder BW Used Per Carrier (x[***]) (%): [***] # = deltas used | ||||
Transponder Power Used Per Carrier (%): [***] ! = modif. default | ||||
Transponder Bandwidth Allocation (MHz): [***] * = users input |
OPT-048537 / SPID-4-8199R1 | Intelsat Confidential and Proprietary | Page 14 of 14 | ||
SS / 27-Jul-15 | V5./14 August 2013 |