Amended and Restated NoNotice Storage and Transportation Delivery Service Agreement Rate Schedule NNT1 between Colorado Interstate Gas Company, L.L.C. and Public Service Company of Colorado, a Colorado corporation (Shipper) Dated: October 1, 2001, amended and restated as of: May 1, 2012 Amended and Restated No-Notice Storage and Transportation Delivery Service Agreement (Agreement) Rate Schedule NNT-1 Dated: October 1, 2001, amended and restated as of: May 1, 2012
EX-10.1 3 cig-20121231xex101.htm TRANSPORTATION AND STORAGE AGREEMENT CIG-2012.12.31-EX 10.1
Exhibit 10.1
Agreement No. 31050000G
Amended and Restated No‑Notice Storage and Transportation Delivery Service Agreement
Rate Schedule NNT‑1
between
Colorado Interstate Gas Company, L.L.C.
and
Public Service Company of Colorado, a Colorado corporation
(Shipper)
Dated: October 1, 2001, amended and restated as of: May 1, 2012
Amended and Restated No-Notice Storage and Transportation
Delivery Service Agreement (“Agreement”)
Rate Schedule NNT-1
Dated: October 1, 2001, amended and restated as of: May 1, 2012
The Parties identified below, in consideration of their mutual promises, agree as follows:
1. | Transporter: COLORADO INTERSTATE GAS COMPANY, L.L.C. |
2. | Shipper: Public service company of colorado, a Colorado corporation |
3. | Applicable Tariff: Transporter's FERC Gas Tariff, Second Revised Volume No. 1, as the same may be amended or superseded from time to time ("the Tariff"). Capitalized terms used in this Agreement and not defined elsewhere have the meanings given to them in the Tariff. |
4. | Changes in Rates and Terms: Transporter shall have the right to propose to the FERC changes in its rates and terms of service and this Agreement shall be deemed to include any changes which are made effective pursuant to FERC Order or regulation or provisions of law, without prejudice to Shipper's right to protest the same. |
5. | Transportation Service: Transportation Service at and between Point of Withdrawal and Primary Point(s) of Delivery shall be on a firm basis. Delivery of quantities at Secondary Point(s) shall be in accordance with the Tariff. |
6. | Delivery: Transporter agrees to transport and deliver Delivery Quantities to Shipper (or for Shipper's account) at the Point(s) of Delivery identified in the attached Exhibit A. Minimum and maximum delivery pressures, as applicable, are listed on Exhibit A. |
7. | Rates and Surcharges: As set forth in Exhibit B. Transporter and Shipper may also agree to a discount using one of the discount types described in Section 4.16 of the General Terms and Conditions of the Tariff. |
8. | For the period May 1, 2012 through March 31, 2016. |
Maximum Delivery Quantity ("MDQ"): 637,144 Dth per Day.
Maximum Available Capacity ("MAC"): 21,352,477 Dth.
Maximum Daily Injection Quantity ("MDIQ"): 209,980 Dth per Day.
Maximum Daily Withdrawal Quantity ("MDWQ"): 637,144 Dth per Day.
All storage entitlements as stated herein ("MAC", "MDIQ", and "MDWQ") are based on an Average Thermal Content of Gas in Storage of 1,000 Btu per cubic foot. The Available Daily Injection Quantity ("ADIQ"), Available
Exhibit 10.1
Daily Withdrawal Quantity ("ADWQ"), and storage entitlements shall be subject to the General Terms and Conditions of the Tariff and stated on Transporter's Electronic Bulletin Board.
9. | Negotiated Rate: Yes _____ No X |
10. | Term of No-Notice Storage and Transportation Service: |
Beginning: October 1, 2001 Ending: March 31, 2016
11. | Notices, Statements, and Bills: |
To Shipper:
Invoices:
Public Service Company of Colorado
1800 Larimer Street, Suite 1200
Denver, CO 80202-4256
Attn: Manager, Commercial Accounting
All Notices:
Public Service Company of Colorado
1800 Larimer Street, Suite 1000
Denver, CO 80202-4256
Attn: Curt Dallinger
To Transporter:
See “Points of Contact” in the Tariff.
12. | Effect on prior Agreement: When this Agreement becomes effective, it shall amend and restate the following agreement between the Parties: The No-Notice Storage and Transportation Delivery Service Agreement between Transporter and Shipper dated September 1, 2011, and referred to as Transporter's Agreement No. 31050000F. |
13. | Municipality Limited Liability: N/A. |
14. | Application of Tariff Provision: N/A. |
15. | Incorporation by Reference: This Agreement in all respects shall be subject to the provisions of the Tariff (as it may be amended pursuant to Section 14 of the Agreement.) |
Exhibit 10.1
IN WITNESS WHEREOF, the Parties have executed this Agreement. This Agreement may be executed by electronic means and an electronic signature shall be treated in all respects as having the same effect as a handwritten signature.
Transporter: | Shipper: |
COLORADO INTERSTATE GAS COMPANY, L.L.C. | PUBLIC SERVICE COMPANY OF COLORADO |
By: /s/ THOMAS L. PRICE | By: /s/ CURTIS C DALLINGER |
Name: Thomas L. Price | Name: Curtis C Dallinger |
Title: Vice President | Title: Director Gas Resource Planning Xcel Energy Services Inc. Authorized Agent for Public Service Company of Colorado |
Accepted and agreed to this | Accepted and agreed to this |
13 day of March, 2012. | 28 day of March, 2012. |
Exhibit 10.1
Agreement No. 31050000G
Exhibit A
to
Amended and Restated No‑Notice Transportation Service Agreement
Rate Schedule NNT‑1
between
Colorado Interstate Gas Company, L.L.C.
and
Public Service Company of Colorado, a Colorado corporation
(Shipper)
Dated: October 1, 2001, amended and restated as of: May 1, 2012
1. | Shipper's Maximum Delivery Quantity ("MDQ"): (See ¶8) |
2. | Shipper's Maximum Available Capacity ("MAC"): (See ¶8) |
3. | Shipper's Maximum Daily Injection Quantity ("MDIQ"): (See ¶8) |
4. | Shipper's Maximum Daily Withdrawal Quantity ("MDWQ"): (See ¶8) |
Primary Point(s) of Delivery (Note 1) | Effective Dates | Primary Point(s) of Delivery Quantity (Dth per Day) (Note A) | Minimum Delivery Pressure p.s.i.g. (Note 3) | Maximum Delivery Pressure p.s.i.g. (Note 3) |
Brush Group (BRS) (Note 6a) | (See ¶8) | 4,000 | ||
East Denver Group (EDE) (Note 6a) | (See ¶8) | 581,029 | ||
First Creek (FSC) (Note 6b) | (See ¶8) | — | Transporter's Line Pressure | 920 |
Ft. Lupton (FTL) (Note 6a) | (See ¶8) | — | 750 | 822 |
Greeley Group (GRE) (Note 6b) | (See ¶8) | — | ||
Pueblo Group (PUE) (Note 6a) | (See ¶8) | 52,115 | ||
Total | 637,144 |
Exhibit 10.1
Exhibit A (cont.) | ||||
Secondary Point(s) of Delivery (Note 1) | Effective Dates | Secondary Point(s) of Delivery Quantity (Dth per Day) (Note 2) | Minimum Delivery Pressure p.s.i.g. (Note 3) | Maximum Delivery Pressure p.s.i.g. (Note 3) |
Aristocrat High (ASH) J92244 (Note 6e) | (See ¶8) | Transporter's Line Pressure | 1,440 | |
Aristocrat Low (AST) J92244 (Note 6c) | (See ¶8) | Transporter's Line Pressure | 850 | |
Beaver Creek Lateral (BCL) J92149 (Note 6c) | (See ¶8) | 151,000 | 500 | 1,000 |
Blue Spruce (BLU) J92088 (Note 6c) | (See ¶8) | Transporter's Line Pressure | 920 | |
Corral Gulch (CRG) K91802 (Note 6d) | (See ¶8) | 700 | 1,000 | |
Fort Lupton High (FLH) J92055 (Note 6e) | (See ¶8) | Transporter's Line Pressure | 1,440 | |
Hudson High (HUD) J92106 (Note 6e) | (See ¶8) | Transporter's Line Pressure | 1,440 | |
Hudson Low Pressure (HSN) J92106 (Note 6c) | (See ¶8) | 550 | 1,440 | |
Little Horse (LTH) K91778 (Note 6d) | (See ¶8) | 700 | 1,000 | |
Lodgepole (LPM) J91989 (Note 6d) | (See ¶8) | 753 | 850 | |
Midway Public Service (MWP) (Note 6c) | (See ¶8) | 165 | 614 | |
Midway PSCo High (MPH) (Note 6e) | (See ¶8) | 490 | 1,440 | |
Ponderosa (PON) J96046 (Note 6d) | (See ¶8) | 920 | Transporter's Line Pressure | |
Rifle (RIF) J92291 (Note 6d) | (See ¶8) | 750 | 1,116 | |
Skyline (SKL) J91807 (Note 6c) | (See ¶8) | 550 | 822 | |
St. Vrain (STV) J92191 (Note 6e) | (See ¶8) | Transporter's Line Pressure | 1,440 |
NOTES:
(A)Attached below is a table entitled “Primary Points of Delivery” that details the individual Primary Point(s) of Delivery, Points of Delivery Quantity, and delivery pressures. Shipper shall have the right to take Delivery of quantities up to the group aggregate limit listed above at any point within the group subject to the lesser of the Primary Point of Delivery Quantity or the meter capacity.
Exhibit 10.1
Primary Point(s) of Delivery
Primary Point(s) of Delivery (Note 1) | Effective Dates | Primary Point(s) of Delivery Quantity (Dth per Day) (Note 2) | Minimum Delivery Pressure p.s.i.g. (Note 3) | Maximum Delivery Pressure p.s.i.g. (Note 3) |
Ft. Lupton (FTL) | (See ¶8) | 68,280 | 750 | 822 |
EAST DENVER GROUP DRN: 2167 | ||||
Arapahoe Hills | (See ¶8) | 156 | Transporter's Line Pressure | Transporter's Line Pressure |
East Denver (EDE) J91077 | (See ¶8) | 482,040 | 250 | 285 |
East Quincy (EDE) J91081 | (See ¶8) | 48,464 | 280 | 720 |
Grimm (EDE) J91078 | (See ¶8) | 360 | 200 | 400 |
Harvest Mile (EDE) J92202 | (See ¶8) | 2,700 | 285 | 820 |
Hidden Village (EDE) | (See ¶8) | 521 | Transporter's Line Pressure | 820 |
Inspiration Point (EDE) J91079 | (See ¶8) | 106 | (Note 4) | 820 |
Mesa (EDE) J91107 | (See ¶8) | 403,000 | 275 | 740 |
Schaeffer Weeks (EDE) J91080 | (See ¶8) | 2,948 | 200 | 740 |
Second Creek (EDE) J91827 | (See ¶8) | 1,424 | 400 | 822 |
Smokey Hill (EDE) J92037 DRN: 283184 | (See ¶8) | 10,558 | (Note 4) | 820 |
Whispering Pines (EDE) J91777 | (See ¶8) | 270,805 | (Note 5) | 650 |
GREELEY GROUP DRN:2771 | ||||
Ault (GRE) J91110 | (See ¶8) | 91,400 | 550 | 850 |
Greeley (GRE) J91109 | (See ¶8) | 75,500 | 550 | 850 |
Norfolk | (See ¶8) | 10,750 | 460 | 850 |
Exhibit 10.1
Exhibit A (cont.) | ||||
Primary Point(s) of Delivery (Note 1) | Effective Dates | Primary Point(s) of Delivery Quantity (Dth per Day) (Note 2) | Minimum Delivery Pressure p.s.i.g. (Note 3) | Maximum Delivery Pressure p.s.i.g (Note 3) |
PUEBLO GROUP DRN: 41449: | ||||
Air Base (PUE) J91088 | (See ¶8) | 1,559 | 100 | 100 |
B.F. Goodrich (PUE) DRN: 134584 & MS#J91689 | (See ¶8) | 159 | 100 | 337 |
Colorado Fire Clay Co. (PUE) | (See ¶8) | 256 | Transporter's Line Pressure | 659 |
Comanche Power Plant (CPP) J91700 | (See ¶8) | 15,000 | 200 | 400 |
Dave Fountain Tap (PUE) | (See ¶8) | 64 | Transporter's Line Pressure | Transporter's Line Pressure |
Devine (Avondale-Boone) (PUE) J91089 | (See ¶8) | 962 | 150 | 150 |
Hendrick Tap (PUE) | (See ¶8) | 90 | Transporter's Line Pressure | Transporter's Line Pressure |
Pinon (PUE) | (See ¶8) | 39 | Transporter's Line Pressure | 614 |
Pueblo County Poor Farm (PUE) J91090 | (See ¶8) | 1,689 | 150 | 150 |
Pueblo North (PUE) J91086 | (See ¶8) | 21,310 | 150 | 150 |
Pueblo South (PUE) J91087 | (See ¶8) | 43,790 | 225 | 225 |
Pueblo West (PUE) J91091 | (See ¶8) | 14,400 | 285 | 285 |
Pueblo West Reserve (PUE) J92026 | (See ¶8) | 480 | 285 | 285 |
Vineland (PUE) J91092 | (See ¶8) | 650 | 50 | 50 |
Welton Ditch Company Tap | (See ¶8) | 127 | Transporter's Line Pressure | Transporter's Line Pressure |
BRUSH GROUP DRN: 41446: | ||||
Brush (BRS) J91082 | (See ¶8) | 4,741 | 125 | 125 |
Fort Morgan Country Club (BRS) J91083 | (See ¶8) | 272 | 150 | 150 |
Wauketa (Log Lane) J91084 | (See ¶8) | 1,361 | 90 | 90 |
Wiggins/Roundup (BRS) J91112 | (See ¶8) | 36,131 | 600 | 1,000 |
Brush Grp Hiline Tap including: | 1,358 | |||
3T Cattle Company | (See ¶8) | Transporter's Line Pressure | 825 | |
Front Range Airport | (See ¶8) | Transporter's Line Pressure | 1,000 | |
Tom Cooper | (See ¶8) | Transporter's Line Pressure | 825 | |
John Yager Tap | (See ¶8) | Transporter's Line Pressure | 1,050 |
NOTES:
(1) Point(s) of Delivery eligible for service are referenced in Section 30 of the General Terms and Conditions of the Tariff.
(2) The sum of the Delivery Quantities at Point(s) of Delivery shall not be greater than Shipper's MDQ.
(3) Pressure conditions shall be in accordance with Section 5.4 of the General Terms and Conditions of the Tariff.
(4) Maximum pressure is line pressure not less than 350 p.s.i.g. in November, December, January, and February; not less than 325 p.s.i.g. in September, October, March, and April; and not less than 260 p.s.i.g. in May, June, July, and August.
(5) Not less than 325 p.s.i.g. in March - October, not less than 400 p.s.i.g. in November - February except during peak day operations (expected ambient temperatures of less than -5 Degrees Fahrenheit) when 500 p.s.i.g. can be supported for periods
Exhibit 10.1
up to 3 consecutive 24 hour periods when requested by phone or electronic mail with 12 hours notice to Transporter of need and the availability of peak day storage deliverability.
(6) Subject to Section 30 of the tariff, the location service descriptions are:
a.Primary NNT Balancing Point with entitlement. Hourly service with peak hour transfer. (Section 30.1)
b.Primary NNT Balancing Point without entitlement. Hourly service with peak hour transfer. (Section 30.2)
c.Secondary NNT Balancing Point-. Hourly service with peak hour transfer. (Section 30.4)
d.Secondary NNT Balancing Point. Daily balancing only with no hourly service. (Section 30.3)
e.Secondary NNT Balancing Point. Hourly NNT service with peak hour transfer based on high pressure HEEN option. (Section 30.4(a))
Exhibit 10.1
Agreement No. 31050000G
Exhibit B
to
Amended and Restated No‑Notice Transportation Service Agreement
Rate Schedule NNT‑1
between
Colorado Interstate Gas Company, L.L.C.
and
Public Service Company of Colorado, a Colorado corporation
(Shipper)
Dated: October 1, 2001, amended and restated as of: May 1, 2012
Quantity Injection/Withdrawal Rate | Fuel Reimbursement | Surcharges | |
Storage Injection………………….............................. | (Note 1) | (Note 2) | (Note 3) |
Primary Point(s) of Delivery (Note 4) | R1 Reservation Rate | Quantity Delivery Rate | Effective Dates | Surcharges |
As listed on Exhibit A | (Note 1) | (Note 1) | (See ¶8) | (Note 3) |
NOTES:
(1) | Unless otherwise agreed by the Parties in writing, the rates for service shall be Transporter's maximum rates for service under Rate Schedule NNT‑1 or other superseding Rate Schedule, as such rates may be changed from time to time. |
(2) | Fuel Reimbursement shall be as stated on Transporter's Schedule of Surcharges and Fees in The Tariff, as they may be changed from time to time, unless otherwise agreed between the Parties. Quantities scheduled by Transporter from/to Primary and/or Secondary or Segmented Point(s) on any off-system capacity held by Transporter shall be subject to Transporter's Third Party Charges as described on Transporter's EBB and/or pursuant to Section 4.3 of the General Terms and Conditions of the Tariff. |
(3) | Applicable Surcharges: |
All applicable surcharges, unless otherwise specified, shall be the maximum surcharge rate as stated in the Schedule of Surcharges and Fees in The Tariff, as such surcharges may be changed from time to time.
Gas Quality Control Surcharge:
The Gas Quality Control Reservation Rate and commodity rate shall be assessed pursuant to Section 17.4 of the General Terms and Conditions set forth in the Tariff.
ACA:
The ACA Surcharge shall be assessed pursuant to Section 17.2 of the General Terms and Conditions as set forth in The Tariff.
(4) | Point(s) of Delivery eligible for service are described in Section 30 of the General Terms and Conditions of the Tariff and posted on Transporter's Electronic Bulletin Board. |